15kV PT Connector, European Separable Elbow Connector with Flexible Jumper Cable
15kV PT Connector, European Separable Elbow Connector with Flexible Jumper Cable
15kV PT Connector, European Separable Elbow Connector with Flexible Jumper Cable
+
  • 15kV PT Connector, European Separable Elbow Connector with Flexible Jumper Cable
  • 15kV PT Connector, European Separable Elbow Connector with Flexible Jumper Cable
  • 15kV PT Connector, European Separable Elbow Connector with Flexible Jumper Cable

Product Details

  • Product Details
  • Machine Unit
    • Commodity name: 15kV PT Connector, European Separable Elbow Connector with Flexible Jumper Cable

    Model: 15kV Rated current: up to 1250A Material: EPDM Application: Electrical equipment in parallel(Screened type) Bushing model: EN50180 & 50181 interface C Execution Standards: IEC60502.4, GB/T12706.4

    Product Description

    • The top busbar connector is suitable for busbar connection between gas-insulated ring main units (RMU), Gi5 switchgear and other switchgear in 27.5kV railway systems and power systems up to 40.5kV. It mates with C-type bushings per EN50181 and DIN47637 standards. Product performance complies with GB/T 12706.4 and IEC 60502 standards.

     

     Key Features

    • Fully screened and fully insulated design, touch-safe outer surface, prevents electric shock risk
    • Silicone rubber material, excellent aging and weather resistance, long service life
    • Screened type with built-in grounding device, screening resistance ≤5kΩ, safe and reliable operation
    • Partial discharge ≤10pC at 15kV, effectively prevents insulation aging
    • Compatible with EN50180/50181 Interface C bushings, high interchangeability, fits   mainstream RMU
    • Supports double-cabinet and triple-cabinet combinations, center distance customizable
    • Easy installation, maintenance-free, suitable for rapid on-site assembly

     

     Models & Technical Parameters

    ProductName

    RatedVoltage

    RatedCurrent

    ACWithstand

    PartialDischarge

    LightningImpulse

    ScreeningResistance

    CableSection

    (mm²)


    15kV European Screened Busbar Connector
    (Double-cabinet)

    15kV

    630A

    42kV/min

    ≤10pC @15kV

    95kV

    ≤5kΩ

    25-400


    Triple-Cabinet Busbar Connector
    (Screened)

    15kV

    630A

    42kV/min

    ≤10pC @15kV

    95kV

    ≤5kΩ

    —


    15kV European Non-Screened Busbar Connector
    (Double-cabinet)

    15kV

    630A

    42kV/min

    ≤10pC @15kV

    95kV

    —

    25-400

      Model Selection Guide

    Type

    Description

    Screened

    With external grounding device, yellow-green grounding wire visible; for cabinets requiring screening and grounding, touch-safe during operation

    Non-screened

    No grounding device, grey appearance; for cabinets with built-in screening or no special grounding requirements

    Double-cabinet

    T-connectors at both ends, connects two switchgear cabinets, most commonly used

    Triple-cabinet

    Additional T-branch connector in the middle, enables busbar through-connection of three cabinets

    Applications

    • Double/triple cabinet parallel expansion of gas-insulated Ring Main Units (RMU)
    • Busbar interconnection for Gi5 switchgear and other MV switchgear
    • 27.5kV railway system distribution switchgear connection
    • Combination of switchgear assemblies in power systems up to 40.5kV
    • Internal busbar connection in compact substations and box-type substations
    • Expansion and retrofit projects of existing switchgear

     


Product Consultation

*Warm reminder: Please be sure to fill in the information accurately and keep the communication open. We will contact you as soon as possible.

Submit

Related Products

35KV indoor Silicone Cold Shrink Cable Termination Kit for XLPE Power Cables

Model: 35KV Adapter max size: 400mm² Material: Liquid Silicone Rubber Application: Cable termination Applicable cables: XLPE, PVC, EPR, etc. Execution Standards: IEC60502.4, GB/T12706.4

View Details

35KV outdoor Silicone Cold Shrink Cable Termination Kit for XLPE Power Cables

Model: 35KV Adapter max size: 400mm² Material: Liquid Silicone Rubber Application: Cable termination Applicable cables: XLPE, PVC, EPR, etc. Execution Standards: IEC60502.4, GB/T12706.4

View Details

10kV Cold-Shrinkable Cable Joint (Intermediate Connector)

Model: 10kV Adapter max size: 630mm² Material: Liquid Silicone Rubber Application:Cable connection Applicable cables: XLPE, PVC, EPR, etc. Execution Standards: IEC60502.4, GB/T12706.4

View Details

15kV PT Connector, European Separable Elbow Connector with Flexible Jumper Cable
15kV PT Connector, European Separable Elbow Connector with Flexible Jumper Cable
15kV PT Connector, European Separable Elbow Connector with Flexible Jumper Cable
+
  • 15kV PT Connector, European Separable Elbow Connector with Flexible Jumper Cable
  • 15kV PT Connector, European Separable Elbow Connector with Flexible Jumper Cable
  • 15kV PT Connector, European Separable Elbow Connector with Flexible Jumper Cable

15kV PT Connector, European Separable Elbow Connector with Flexible Jumper Cable


Summary Description:

Model: 15kV Rated current: up to 1250A Material: EPDM Application: Electrical equipment in parallel(Screened type) Bushing model: EN50180 & 50181 interface C Execution Standards: IEC60502.4, GB/T12706.4

Share to: