- Commodity name: Triple-Cabinet Busbar Connector
Model: 15kV Rated current: up to 1250A Material: EPDM Application: Electrical equipment in parallel(Screened type) Bushing model: EN50180 & 50181 interface C Execution Standards: IEC60502.4, GB/T12706.4
Product Description
- The top busbar connector is suitable for busbar connection between gas-insulated ring main units (RMU), Gi5 switchgear and other switchgear in 27.5kV railway systems and power systems up to 40.5kV. It mates with C-type bushings per EN50181 and DIN47637 standards. Product performance complies with GB/T 12706.4 and IEC 60502 standards.
Key Features
- Fully screened and fully insulated design, touch-safe outer surface, prevents electric shock risk
- Silicone rubber material, excellent aging and weather resistance, long service life
- Screened type with built-in grounding device, screening resistance ≤5kΩ, safe and reliable operation
- Partial discharge ≤10pC at 15kV, effectively prevents insulation aging
- Compatible with EN50180/50181 Interface C bushings, high interchangeability, fits mainstream RMU
- Supports double-cabinet and triple-cabinet combinations, center distance customizable
- Easy installation, maintenance-free, suitable for rapid on-site assembly
Models & Technical Parameters
ProductName
RatedVoltage
RatedCurrent
ACWithstand
PartialDischarge
LightningImpulse
ScreeningResistance
CableSection
(mm²)
15kV European Screened Busbar Connector
(Double-cabinet)15kV
630A
42kV/min
≤10pC @15kV
95kV
≤5kΩ
25-400
Triple-Cabinet Busbar Connector
(Screened)15kV
630A
42kV/min
≤10pC @15kV
95kV
≤5kΩ
—
15kV European Non-Screened Busbar Connector
(Double-cabinet)15kV
630A
42kV/min
≤10pC @15kV
95kV
—
25-400
Model Selection Guide
Type
Description
Screened
With external grounding device, yellow-green grounding wire visible; for cabinets requiring screening and grounding, touch-safe during operation
Non-screened
No grounding device, grey appearance; for cabinets with built-in screening or no special grounding requirements
Double-cabinet
T-connectors at both ends, connects two switchgear cabinets, most commonly used
Triple-cabinet
Additional T-branch connector in the middle, enables busbar through-connection of three cabinets
Applications
- Double/triple cabinet parallel expansion of gas-insulated Ring Main Units (RMU)
- Busbar interconnection for Gi5 switchgear and other MV switchgear
- 27.5kV railway system distribution switchgear connection
- Combination of switchgear assemblies in power systems up to 40.5kV
- Internal busbar connection in compact substations and box-type substations
- Expansion and retrofit projects of existing switchgear
Belongs to category:
Product Consultation
Related Products
35KV indoor Silicone Cold Shrink Cable Termination Kit for XLPE Power Cables
35KV outdoor Silicone Cold Shrink Cable Termination Kit for XLPE Power Cables
10kV Cold-Shrinkable Cable Joint (Intermediate Connector)
Triple-Cabinet Busbar Connector
Summary Description:
Keywords: